Packaging parameters:
Product model |
Quantity (sets/carton) |
Package size(cm) |
Package weight (kg/carton) |
M8×110 |
|
|
|
M10×130 |
|
|
|
M12×160 |
|
|
|
M16×190 |
|
|
|
M20×260 |
|
|
|
M24×300 |
|
|
|
M30×380 |
|
|
|
Technical parameters(mm)
Product model |
Drilling diameter |
Drilling depth |
Anchorage thickness(max) |
Substrate thickness(min) |
Screw length |
M8×110 |
10 |
80 |
15 |
140 |
110 |
M10×130 |
12 |
90 |
20 |
160 |
130 |
M12×160 |
14 |
110 |
25 |
210 |
160 |
M16×190 |
18 |
125 |
35 |
210 |
190 |
M20×260 |
25 |
170 |
65 |
340 |
260 |
M24×300 |
28 |
210 |
65 |
370 |
300 |
M30×380 |
35 |
270 |
70 |
540 |
380 |
Design Parameters(KN)
Product model |
M8 |
M10 |
M12 |
M16 |
M20 |
M24 |
M30 |
|
Tensile design reference for C30 non-cracked concrete |
5.8grade |
9.3 |
13.8 |
19.8 |
30.9 |
52.4 |
87.5 |
133.6 |
8.8 grade |
12.4 |
16.8 |
22.9 |
34.5 |
58.8 |
87.5 |
133.6 |
|
A2-70 |
11.8 |
15.3 |
20.8 |
32.3 |
55.8 |
87.5 |
133.6 |
|
A4-80 |
12.4 |
16.8 |
22.9 |
34.5 |
58.8 |
87.5 |
133.6 |
|
Shear design reference for C30 non-cracked concrete |
5.8 grade |
6.8 |
10.5 |
14.5 |
27.8 |
45.5 |
65.5 |
121.3 |
8.8 grade |
8.3 |
13.1 |
19.0 |
32.3 |
55.2 |
82.0 |
132.6 |
|
A2-70 |
7.9 |
12.6 |
18.3 |
29.0 |
51.4 |
75.5 |
137.5 |
|
A4-80 |
8.3 |
13.1 |
19.0 |
32.3 |
55.2 |
82.0 |
132.6 |
Hose chemical reaction time reference
Substrate temperature |
Hardening time |
-5℃—0℃ |
5h |
0℃—10℃ |
1h |
10℃—20℃ |
30min |
>20℃ |
20min |
Operating procedures:
1. Use straight hole drills to drill holes of corresponding diameter and depth
2. Use the soot blower to sweep ash more than 2 times
3. Use a brush to clean hole dust more than 2 times
4. Use the soot blower again to sweep ash until the hole has no dust overflow
5. Insert chemical anchors hose
6. Use a torque drill to screw in a high-strength chemical anchor to complete the anchoring
P.s. Electric hammer, drills, soot blowers, brush, torque drills and mounting connector will be used during the operation. Jiraw is equipped with a brush and mounting connector as standard. Soot blowers are presented in proportion to the quantity. Others are purchased on demand.